Molds & Tooling
2 views
Improper cooling water channels affect product quality and production efficiency
Problem Phenomenon
Improper cooling water channels affect product quality and production efficiency
Cause Analysis
Uneven cooling water channel layout, local cooling too fast or too slow
Water channel diameter too small, insufficient flow, low cooling efficiency
Water channel too far from the cavity, poor cooling effect
Water channel blocked or scaled, cooling efficiency decreased
Asymmetric water channels for each cavity in multi-cavity molds
Solution
Optimize cooling water channel layout to ensure uniformity
Increase water channel diameter to improve flow
Shorten the distance between water channel and cavity
Regularly clean water channel blockages
Ensure symmetric water channel arrangement for multiple cavities
Key Takeaway
Cooling water channels need a uniform and efficient layout