Improper cooling water channels affect product quality and production efficiency
Fenómeno del problema
Improper cooling water channels affect product quality and production efficiency
Análisis de la causa
Uneven cooling water channel layout, local cooling too fast or too slow
Water channel diameter too small, insufficient flow, low cooling efficiency
Water channel too far from the cavity, poor cooling effect
Water channel blocked or scaled, cooling efficiency decreased
Asymmetric water channels for each cavity in multi-cavity molds
Solución
Optimize cooling water channel layout to ensure uniformity
Increase water channel diameter to improve flow
Shorten the distance between water channel and cavity
Regularly clean water channel blockages
Ensure symmetric water channel arrangement for multiple cavities
Conclusión clave
Cooling water channels need a uniform and efficient layout