Improper cooling water channels affect product quality and production efficiency

Fenómeno del problema
Improper cooling water channels affect product quality and production efficiency
Análisis de la causa
Uneven cooling water channel layout, local cooling too fast or too slow Water channel diameter too small, insufficient flow, low cooling efficiency Water channel too far from the cavity, poor cooling effect Water channel blocked or scaled, cooling efficiency decreased Asymmetric water channels for each cavity in multi-cavity molds
Solución
Optimize cooling water channel layout to ensure uniformity Increase water channel diameter to improve flow Shorten the distance between water channel and cavity Regularly clean water channel blockages Ensure symmetric water channel arrangement for multiple cavities
Conclusión clave
Cooling water channels need a uniform and efficient layout