Menu
Materials Machinery
Insights
Articles Videos Problem & Solution
About
About Chembull Media Partners
Contact Us
Language
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Back to Problem & Solution
Injection Molding 3 views

CEF surface corrugation periodic

Problem Phenomenon
The surface of the CEF product has periodic corrugations with a spacing of 5-15mm
Cause Analysis
The injection speed fluctuates periodically; the hydraulic system is unstable; the screw speed is unstable
Solution
1) Overhaul the injection system to stabilize the pressure and speed; 2) Servo motor drive instead of hydraulic drive; 3) PID control to stabilize the injection parameters
Key Takeaway
Corrugations are caused by unstable injection; equipment overhaul and PID control are the key
CEFsurface corrugationinjection stabilityequipment overhaulPID control