Menu
Materials Machinery
Insights
Articles Videos Problem & Solution
About
About Chembull Media Partners
Contact Us
Language
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Back to Problem & Solution
Injection Molding 3 views

Glass Fibre '2079851475616104452 warpage deformation

Problem Phenomenon
Glass Fibre injection molded product warps 2-3mm/100mm after demolding, flatness not up to standard
Cause Analysis
Glass Fibre shrinkage rate large and mold temperature uneven causes anisotropic shrinkage differences; improper gate position, flow orientation stress released unevenly; cooling time insufficient
Solution
1) Raise mold temperature to 40-60°C to reduce temperature difference; 2) increase holding pressure 50-70MPa; 3) optimize gate position for uniform flow; 4) extend cooling time; 5) annealing treatment to release residual stress
Key Takeaway
Warpage is caused by shrinkage differences and orientation stress; uniform mold temperature and holding pressure are key
Glass Fibre injectionwarpageshrinkage rateholding pressureannealing treatment

Was this helpful?

0 people found this helpful

ChemAI