Molds & Tooling 2 views

POE fatigue resistance poor

Problem Phenomenon
POE product fatigue life <10⁴ cycles, below 10⁵ cycles requirement
Cause Analysis
POE elastic recovery insufficient, each cycle accumulates plastic deformation; crosslinking degree low, fatigue crack propagates fast
Solution
1) Increase crosslinking degree to improve recovery and reduce accumulated deformation; 2) Select high molecular weight grade to raise fatigue threshold; 3) Product design to reduce stress concentration
Key Takeaway
Poor fatigue resistance is caused by insufficient recovery and fast crack propagation; increasing crosslinking is key
POEfatigue resistancecrosslinking degreemolecular weightstress concentration