Molds & Tooling
8 visualizaciones
POE fatigue resistance poor
Fenómeno del problema
POE product fatigue life <10⁴ cycles, below 10⁵ cycles requirement
Análisis de la causa
POE elastic recovery insufficient, each cycle accumulates plastic deformation; crosslinking degree low, fatigue crack propagates fast
Solución
1) Increase crosslinking degree to improve recovery and reduce accumulated deformation; 2) Select high molecular weight grade to raise fatigue threshold; 3) Product design to reduce stress concentration
Conclusión clave
Poor fatigue resistance is caused by insufficient recovery and fast crack propagation; increasing crosslinking is key
¿Le ha resultado útil?
0 personas encontraron esto útil