Production & Quality
2 views
Insufficient chlorine gas permeation resistance
Problem Phenomenon
Permeation stress cracking in chlorine gas environment
Cause Analysis
Crystallinity about 40%, amorphous region permeation, ESC
Solution
Slow cooling to increase crystallinity to 50%, annealing treatment
Key Takeaway
Chlorine resistance is related to crystallinity and stress level