Galvanic corrosion of carbon fiber in contact with metal

Problem Phenomenon
Galvanic corrosion occurs between carbon fiber and metal parts in an electrolyte environment
Cause Analysis
The potential difference between carbon fiber and metals (aluminum, steel, etc.)
Solution
Use an electrically insulating layer to isolate carbon fiber from metal; select suitable metal materials
Key Takeaway
Carbon fiber-metal galvanic corrosion must be considered in structural design