Production & Quality
10 visualizações
Galvanic corrosion of carbon fiber in contact with metal
Fenómeno do problema
Galvanic corrosion occurs between carbon fiber and metal parts in an electrolyte environment
Análise das causas
The potential difference between carbon fiber and metals (aluminum, steel, etc.)
Solução
Use an electrically insulating layer to isolate carbon fiber from metal; select suitable metal materials
Conclusão principal
Carbon fiber-metal galvanic corrosion must be considered in structural design
Isto foi útil?
0 pessoas acharam isto útil