Menu
Materials Machinery
Insights
Articles Videos Problem & Solution
About
About Chembull Media Partners
Contact Us
Language
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Back to Problem & Solution
Extrusion & Post 10 views

Longitudinal reversion of homopolymer polypropylene pipes exceeding standard

Problem Phenomenon
After the pipe is heated under specified temperature and time conditions, the longitudinal reversion exceeds the standard limit. Excessive reversion reflects large internal stress or incomplete crystallization of the pipe, affecting pipe use reliability.
Cause Analysis
(1) Large residual internal stress in homopolymer polypropylene after extrusion (2) Cooling rate too fast; molecular chain orientation not relaxed (3) Haul-off speed too high; excessive longitudinal stretching of the pipe (4) Barrel temperature too low, insufficient melt plasticization (5) Insufficient sizing cooling
Solution
(1) Appropriately increase barrel temperature to a reasonable value within the 200-280°C range, improve plasticization (2) Appropriately reduce cooling rate, allow molecular chains relaxation time (3) Adjust haul-off speed, reduce draw ratio (4) Increase cooling water tank length, ensure full cooling (5) Perform water bath annealing after pipe demolding to eliminate internal stress
Key Takeaway
Excessive reversion is caused by large internal stress or excessive orientation; it needs to be solved from temperature control, cooling rate, and haul-off speed.
longitudinal reversioninternal stresscooling ratehaul-off speedmolecular orientation