Blow Molding
2 views
PCTG '2079851475616104457 parison sag
Problem Phenomenon
In extrusion '2079851475616104457, the parison is too long and sags, causing uneven wall thickness.
Cause Analysis
Insufficient melt strength (processing temperature too high), the parison is too long and hangs for a long time.
Solution
Lower the processing temperature to increase melt strength; use an accumulator head; increase parison wall thickness.
Key Takeaway
PCTG '2079851475616104457 parison control is the key to wall thickness uniformity.
Was this helpful?
0 people found this helpful