Improper blowing pressure, time, and speed settings affecting container quality

Problem Phenomenon
Improper blowing pressure, time, and speed settings affect container quality
Cause Analysis
Insufficient blowing pressure, container not fully expanded Blowing time too short, uneven wall thickness Blowing speed too fast, container locally too thin Blowing pressure too high, container deforms or bursts Improper switching between pre-blowing and main blowing
Solution
Reasonably set blowing pressure 0.5-1.0MPa Extend blowing time to ensure full expansion Control blowing speed to avoid being too fast Avoid excessive blowing pressure Optimize switching between pre-blowing and main blowing
Key Takeaway
Blowing process needs reasonable pressure and time settings