Injection Molding
2 visualizações
PC Injection Machine Screw Wear Acceleration
Fenómeno do problema
After processing glass fiber reinforced PC, the screw and check ring wear quickly, and metering fluctuates.
Análise das causas
Glass fiber strongly wears metal, and ordinary nitrided screws have a short service life; after wear, plasticizing and metering become unstable, and product quality fluctuates.
Solução
①Use bimetallic/hardened screws and barrels for GF-PC; ②Regularly check the check ring clearance; ③Monitor the trend of plasticizing time changes.
Conclusão principal
Glass fiber material must be equipped with a wear-resistant plasticizing system.
Isto foi útil?
0 pessoas acharam isto útil