PP Glass Fiber Reinforced Warpage
Fenómeno do problema
GF-PP flat parts warp along a fixed direction; uneven cooling adjustments are ineffective.
Análise das causas
Glass fiber orientation causes flow-direction/transverse shrinkage differences; gate position determines orientation direction.
Solução
①Adjust gate position; ②Moldflow fiber orientation analysis; ③balance holding pressure; ④select low-warpage mineral/glass fiber hybrid filled grades.
Conclusão principal
Orientation warpage is broken through from gate design.