Extrusion & Post
13 visualizações
Slow curing of PU coating
Fenómeno do problema
PU coating cures at room temperature >24h, below the 8h requirement
Análise das causas
Curing agent NCO/OH ratio too low <1.0; low ambient humidity <40%RH delays curing
Solução
1) Increase NCO/OH ratio to 1.1-1.2; 2) Control ambient humidity at 50-70%RH to accelerate curing; 3) Add 0.1wt% drier
Conclusão principal
PU coating curing speed is determined by NCO/OH ratio and humidity
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!