Thermoforming
7 visualizações
Uneven thickness of PET extruded sheet
Fenómeno do problema
The transverse thickness of PET extruded sheet fluctuates greatly, thin in the middle and thick on both sides or vice versa, affecting subsequent '2079851475616104458.
Análise das causas
Die lip gap adjustment is improper; melt temperature distribution is uneven, causing viscosity differences; the three-roll calender gaps are not parallel.
Solução
Precisely adjust die lip bolts, using automatic die lip control; optimize the temperature of each section; calibrate the three-roll gaps and check roll temperature uniformity.
Conclusão principal
PET sheet thickness uniformity requires coordinated control of multiple links.
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!