Thermoforming
7 visualizações
PETG '2079851475616104458 mold surface temperature low
Fenómeno do problema
The mold surface temperature is lower than the set requirement, and the product is poorly formed.
Análise das causas
The mold heating system power is insufficient or partially damaged, and the mold has poor contact with the heating plate.
Solução
Check the heating system and replace damaged elements; ensure good thermal contact; add insulation measures.
Conclusão principal
Insufficient PETG '2079851475616104458 mold temperature causes poor forming.