Injection Molding 6 görüntüleme

EVOH '2079851475616104452 Flow Marks

Sorun Belirtisi
EVOH injection molded product surfaces show radial flow marks centered on the gate
Neden Analizi
Injection speed too fast causing unstable melt front; mold temperature too low <30°C, the front cools rapidly forming marks
Çözüm
1) Use multi-stage injection speed slow-fast-slow to control front stability; 2) Increase mold temperature to 40-50°C to delay front cooling; 3) Stabilize injection pressure to avoid fluctuations; 4) Increase gate area to reduce sudden pressure changes at the gate
Temel Çıkarım
Flow marks are caused by unstable injection front and rapid cooling; multi-stage injection and high mold temperature are key
EVOH injectionflow markinjection speedmold temperaturegate area