Injection Molding
1 visualizações
EVOH '2079851475616104452 Flow Marks
Fenómeno do problema
EVOH injection molded product surfaces show radial flow marks centered on the gate
Análise das causas
Injection speed too fast causing unstable melt front; mold temperature too low <30°C, the front cools rapidly forming marks
Solução
1) Use multi-stage injection speed slow-fast-slow to control front stability; 2) Increase mold temperature to 40-50°C to delay front cooling; 3) Stabilize injection pressure to avoid fluctuations; 4) Increase gate area to reduce sudden pressure changes at the gate
Conclusão principal
Flow marks are caused by unstable injection front and rapid cooling; multi-stage injection and high mold temperature are key
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!