Material Drying
6 مشاهدة
ASA moisture content target management
ظاهرة المشكلة
[Problem phenomenon] ASA drying released based on time, moisture content fluctuates greatly, product appearance varies between good and bad
تحليل الأسباب
Moisture content target is about below 0.05%, which cannot be guaranteed by drying time alone: environmental humidity, material layer thickness, dryer performance differences all affect the endpoint; moisture meter measurement is the release basis
الحل
Equip a moisture analyzer for batch sampling; release when moisture content ≤0.05%; drying parameters fine-tuned with seasonal humidity and recorded; after adjustment, continuously sample to verify the effect, and resume mass production after confirming stability
الخلاصة الأساسية
ASA drying looks at moisture content not the clock, only release below 0.05%; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for subsequent similar problems
هل كان هذا مفيدًا؟
0 شخص وجدوا هذا مفيدًا