Menü
Materialien Maschinen
Einblicke
Artikel Videos Problem & Lösung
About
Über Chembull Medienpartner
Kontaktieren Sie uns
Sprache
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Zurück zu Problem & Lösung
Material Drying 3 Aufrufe

ASA moisture content target management

Problembeschreibung
[Problem phenomenon] ASA drying released based on time, moisture content fluctuates greatly, product appearance varies between good and bad
Ursachenanalyse
Moisture content target is about below 0.05%, which cannot be guaranteed by drying time alone: environmental humidity, material layer thickness, dryer performance differences all affect the endpoint; moisture meter measurement is the release basis
Lösung
Equip a moisture analyzer for batch sampling; release when moisture content ≤0.05%; drying parameters fine-tuned with seasonal humidity and recorded; after adjustment, continuously sample to verify the effect, and resume mass production after confirming stability
Wichtigste Erkenntnis
ASA drying looks at moisture content not the clock, only release below 0.05%; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for subsequent similar problems
moisture contentdryingmoisture meterrelease

War das hilfreich?

0 Personen fanden dies hilfreich

ChemAI