Molds & Tooling
3 Aufrufe
TPU product surface scratch
Problembeschreibung
Dragging scratch marks appear on the surface after demolding.
Ursachenanalyse
Improper demolding timing makes the product overheated and too soft; insufficient demolding draft or cavity surface finish mismatch (over-polishing causes vacuum adsorption instead); during on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based only on experience
Lösung
①extend cooling to improve demolding strength; ②ensure demolding draft; ③adjust cavity surface finish; ④optimize ejection timing; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability
Wichtigste Erkenntnis
TPU surface scratches are related to the demolding state; the surface is not the smoother the better, and appropriate roughness is actually beneficial to demolding; after confirming effectiveness, fix the parameters and practices into the work instruction to prevent recurrence
War das hilfreich?
0 Personen fanden dies hilfreich