Injection Molding 2 Aufrufe

MP Periodic Surface Ripples

Problembeschreibung
Periodic ripples with 5-15mm spacing on the surface of MP products
Ursachenanalyse
Periodic fluctuation of injection speed; unstable hydraulic system; unstable screw rotation speed
Lösung
1) Overhaul the injection system to stabilize pressure and speed; 2) Replace hydraulic drive with servo motor drive; 3) PID control to stabilize injection parameters
Wichtigste Erkenntnis
Ripples are caused by unstable injection; equipment overhaul and PID control are key
MPSurface RipplesInjection StabilityEquipment OverhaulPID Control