Injection Molding
6 visualizações
MP Periodic Surface Ripples
Fenómeno do problema
Periodic ripples with 5-15mm spacing on the surface of MP products
Análise das causas
Periodic fluctuation of injection speed; unstable hydraulic system; unstable screw rotation speed
Solução
1) Overhaul the injection system to stabilize pressure and speed; 2) Replace hydraulic drive with servo motor drive; 3) PID control to stabilize injection parameters
Conclusão principal
Ripples are caused by unstable injection; equipment overhaul and PID control are key
Isto foi útil?
0 pessoas acharam isto útil