Injection Molding
3 visualizaciones
PC holding pressure and sink mark stress
Fenómeno del problema
【Problem Phenomenon】PC holding pressure improper, sink marks and internal stress problems alternate
Análisis de la causa
PC shrinkage rate 0.5-0.7% is small but holding pressure shrinkage compensation is still needed; holding pressure is 40-60% of injection; excessive holding pressure introduces internal stress, especially PC is sensitive
Solución
Holding pressure set at 40-60%; thick-wall rib positions delayed; internal stress parts lower holding pressure with annealing;After adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability
Conclusión clave
PC holding pressure 40-60%, balancing sink marks and stress at both ends;After confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence;Include this case in the defect archive as a reference for troubleshooting similar problems in the future
¿Le ha resultado útil?
0 personas encontraron esto útil
¡Gracias por sus comentarios!