Extrusion & Post
10 visualizaciones
POM Shrinkage Out of Tolerance
Fenómeno del problema
POM part dimensions are smaller than the drawing and inconsistent between batches
Análisis de la causa
POM shrinkage is 1.8-3.5% and is greatly affected by mold temperature and holding pressure; the mold shrinkage value does not match the actual process; during on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based only on experience
Solución
Measure actual shrinkage to correct the mold; lock mold temperature and holding pressure; SPC monitoring of critical dimensions; after adjustment, take continuous samples to verify the effect, and resume mass production only after confirming stability
Conclusión clave
POM dimensional management is based on measured shrinkage; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a troubleshooting reference for subsequent similar problems
¿Le ha resultado útil?
0 personas encontraron esto útil