Molds & Tooling
4 조회수
Mold water channel scaling during product production
문제 현상
Mold cooling efficiency continuously declines and the cycle becomes longer
원인 분석
Excessive cooling water hardness produces scale; electrochemical corrosion occurs between the water channel and the mold metal; water channels have not been maintained for a long time
해결 방법
Use softened water or deionized water as the cooling medium; regularly chemically clean water channels (every 3 months); select corrosion-resistant materials for water channels
핵심 요약
Mold cooling efficiency directly affects the production cycle and product quality