Molds & Tooling
7 visualizações
Mold water channel scaling during product production
Fenómeno do problema
Mold cooling efficiency continuously declines and the cycle becomes longer
Análise das causas
Excessive cooling water hardness produces scale; electrochemical corrosion occurs between the water channel and the mold metal; water channels have not been maintained for a long time
Solução
Use softened water or deionized water as the cooling medium; regularly chemically clean water channels (every 3 months); select corrosion-resistant materials for water channels
Conclusão principal
Mold cooling efficiency directly affects the production cycle and product quality
Isto foi útil?
0 pessoas acharam isto útil