Molds & Tooling
8 visualizaciones
Mold water channel scaling during product production
Fenómeno del problema
Mold cooling efficiency continuously declines and the cycle becomes longer
Análisis de la causa
Excessive cooling water hardness produces scale; electrochemical corrosion occurs between the water channel and the mold metal; water channels have not been maintained for a long time
Solución
Use softened water or deionized water as the cooling medium; regularly chemically clean water channels (every 3 months); select corrosion-resistant materials for water channels
Conclusión clave
Mold cooling efficiency directly affects the production cycle and product quality
¿Le ha resultado útil?
0 personas encontraron esto útil