Molds & Tooling
6 مشاهدة
Mold water channel scaling during product production
ظاهرة المشكلة
Mold cooling efficiency continuously declines and the cycle becomes longer
تحليل الأسباب
Excessive cooling water hardness produces scale; electrochemical corrosion occurs between the water channel and the mold metal; water channels have not been maintained for a long time
الحل
Use softened water or deionized water as the cooling medium; regularly chemically clean water channels (every 3 months); select corrosion-resistant materials for water channels
الخلاصة الأساسية
Mold cooling efficiency directly affects the production cycle and product quality
هل كان هذا مفيدًا؟
0 شخص وجدوا هذا مفيدًا
شكرًا لك على ملاحظاتك!