Molding Process 2 views

LLDPE film corona adhesion problem

Problem Phenomenon
Poor print adhesion.
Cause Analysis
Slip agent blooming + low surface energy; insufficient corona or fast decay.
Solution
①Increase corona power; ②print promptly; ③low-blooming slip system; ④dyne value testing.
Key Takeaway
Adhesion = dyne value management.