Molding Process 20 views

Solvent residue in wet-process PI film

Problem Phenomenon
Residual solvent in PI films prepared by the chemical imidization method
Cause Analysis
Residue of chemical imidization reagents; insufficient washing
Solution
Extend washing time; increase drying temperature; use advanced methods such as supercritical CO₂ extraction
Key Takeaway
Solvent residue affects the electrical and thermal properties of PI films
solvent residuechemical imidizationwashingsupercritical CO2