Molding Process
20 views
Solvent residue in wet-process PI film
Problem Phenomenon
Residual solvent in PI films prepared by the chemical imidization method
Cause Analysis
Residue of chemical imidization reagents; insufficient washing
Solution
Extend washing time; increase drying temperature; use advanced methods such as supercritical CO₂ extraction
Key Takeaway
Solvent residue affects the electrical and thermal properties of PI films
Was this helpful?
0 people found this helpful