Menu
Materials Machinery
Insights
Articles Videos Problem & Solution
About
About Chembull Media Partners
Contact Us
Language
EnglishالعربيةPortuguêsEspañolDeutschTürkçe한국어
Back to Problem & Solution
Injection Molding 4 views

PA6 '2079851475616104452 Metering Fluctuation

Problem Phenomenon
Cushion fluctuation and unstable weight, short shots and flash alternating.
Cause Analysis
PA6 solidifies quickly, and slight leakage of the check ring affects metering; unstable feeding also does; low-viscosity material has high requirements for check ring sealing; during on-site troubleshooting, verify item by item according to this mechanism, and avoid blindly adjusting the machine based only on experience.
Solution
①Disassemble and check the wear and sealing of the check ring, and replace it when necessary;②check hopper feeding and throat cooling to ensure stable and smooth feeding;③stabilize the back pressure setting to ensure consistency of plasticization and metering;④continuously monitor cushion fluctuation as an early warning of metering stability;⑤clean the screw head.
Key Takeaway
Stable PA6 metering = 'check ring health': low-viscosity nylon has extremely high requirements for check ring sealing; cushion fluctuation is the most intuitive alarm; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence.
PA6; metering fluctuation; check ring; cushion

Was this helpful?

0 people found this helpful

ChemAI