Molding Process 2 views

POM product welding problem

Problem Phenomenon
Low ultrasonic welding strength.
Cause Analysis
Welding surface contamination, improper parameters; POM crystalline interface requires precise temperature.
Solution
①Clean the welding surfaces; ②optimize parameters; ③verify strength.
Key Takeaway
Welding = precise interface temperature.
POM;welding;ultrasonic welding;parameters