Molding Process 5 views

Profile die swell

Problem Phenomenon
Profile cross-section size larger than die design value
Cause Analysis
Elastic recovery, exit swell, insufficient design swell compensation
Solution
Correct die dimensions according to die swell ratio
Key Takeaway
Die swell is a key point of extrusion design