Molding Process 5 views

PU processing temperature fluctuation

Problem Phenomenon
During PU processing, temperature fluctuates ±5-8°C, exceeding ±2°C control precision
Cause Analysis
Improper PID parameters of temperature control system; heater bands aged, uneven power; thermocouple position improper, measurement deviation
Solution
1) Re-tune PID parameters; 2) Replace aged heater bands; 3) Adjust thermocouple position to the center of the melt pool
Key Takeaway
Temperature fluctuation is caused by improper temperature control system; PID tuning and heater band replacement are key