Molding Process 5 views

Cable insulation eccentricity

Problem Phenomenon
Insulation layer eccentricity >15%
Cause Analysis
Conductor not centered, die opening not concentric
Solution
Adjust centering and convection
Key Takeaway
Insulation eccentricity affects electrical performance