Molding Process 5 views

Control of FEP product wall thickness

Problem Phenomenon
The wall thickness of FEP profiles is not easy to control
Cause Analysis
FEP melt has poor flowability and uneven filling capacity for each section
Solution
Optimize the die design
Key Takeaway
FEP profiles require die correction based on experience