Molding Process
2 views
Dynamic load fatigue of PAR parts
Problem Phenomenon
Fatigue crack growth characteristics of PAR under cyclic loading.
Cause Analysis
PAR is brittle, and dynamic fatigue cracks expand quickly.
Solution
Control the stress level in fatigue design.
Key Takeaway
PAR fatigue is a key indicator for dynamic applications.
Was this helpful?
0 people found this helpful
Thank you for your feedback!