Molds & Tooling
7 visualizações
HDPE Shrinkage Out of Tolerance
Fenómeno do problema
HDPE product dimensions are smaller than expected and cannot be assembled
Análise das causas
HDPE shrinkage is 1.5-4% with obvious directionality, and mold shrinkage value selection is improper; during on-site troubleshooting, verify item by item according to this mechanism to avoid blindly adjusting the machine based solely on experience
Solução
Measure actual shrinkage to correct the mold; lock the process; SPC for critical dimensions; after adjustment, continuously sample to verify the effect, and resume mass production only after confirming stability; change only one variable at a time and record parameter changes to facilitate locating effective measures
Conclusão principal
HDPE dimensional management is based on measured shrinkage; after confirming effectiveness, solidify the parameters and practices into the work instruction to prevent recurrence; include this case in the defect archive as a reference for troubleshooting similar problems in the future
Isto foi útil?
0 pessoas acharam isto útil
Obrigado pelo seu comentário!