Molds & Tooling
7 visualizações
Glass Fibre insufficient flatness
Fenómeno do problema
Glass Fibre flat plate product flatness >0.5mm/100mm, warpage
Análise das causas
Glass Fibre shrinkage rate large and different in each direction; mold cooling uneven; residual stress release causes continuous warpage
Solução
1) Uniform mold temperature to reduce temperature difference; 2) increase holding pressure to reduce shrinkage difference; 3) annealing to release residual stress
Conclusão principal
Insufficient flatness is caused by shrinkage difference and stress; uniform cooling and annealing are key