Molding Process
4 visualizaciones
MP compression molding incomplete curing
Fenómeno del problema
MP melamine resin compression molded products curing degree <90%, surface has bubbles and soft spots
Análisis de la causa
curing temperature <150°C, low; curing time insufficient <3min; pressure insufficient <10MPa
Solución
1) raise curing temperature to 150-170°C; 2) extend curing time to 5-8min; 3) compression pressure 15-20MPa
Conclusión clave
MP thermoset curing requires the three parameters of temperature, time and pressure to be sufficient
¿Le ha resultado útil?
0 personas encontraron esto útil