CMC Angle Deviation

Problem Phenomenon
Angle deviation of CMC products >1° exceeds the ±0.5° tolerance
Cause Analysis
Uneven shrinkage causes angle changes; mold angle design does not consider CMC shrinkage compensation; product deforms during demolding
Solution
1)Pre-compensate mold angle for CMC shrinkage; 2)Extend cooling time to ensure setting before demolding; 3)Uniform cooling to reduce shrinkage differences
Key Takeaway
Angle deviation is caused by shrinkage and insufficient design compensation; pre-compensation is the key