Molds & Tooling
6 مشاهدة
CEF internal shrinkage cavity
ظاهرة المشكلة
Shrinkage cavities with a diameter of 0.5-2mm appear in the center of the CEF thick-walled product
تحليل الأسباب
The thick-walled area shrinks internally after cooling but the surface has solidified and cannot be fed; the holding pressure time is insufficient and the gate freezes too early
الحل
1) Extend the holding pressure time until the gate is completely frozen; 2) Increase the gate size to delay freezing; 3) Product design to reduce wall thickness differences
الخلاصة الأساسية
Shrinkage cavities are caused by thick wall shrinkage and insufficient holding pressure; extending the holding pressure is the key
هل كان هذا مفيدًا؟
0 شخص وجدوا هذا مفيدًا
شكرًا لك على ملاحظاتك!