Molds & Tooling
6 مشاهدة
MP insufficient flatness
ظاهرة المشكلة
MP flat products flatness >0.5mm/100mm, warpage
تحليل الأسباب
MP shrinkage large and anisotropic; mold cooling uneven; residual stress release causing continuous warpage
الحل
1) uniform mold temperature to reduce temperature difference; 2) increase holding pressure to reduce shrinkage difference; 3) annealing to release residual stress
الخلاصة الأساسية
insufficient flatness is caused by shrinkage difference and stress; uniform cooling and annealing are key
هل كان هذا مفيدًا؟
0 شخص وجدوا هذا مفيدًا
شكرًا لك على ملاحظاتك!